Indirect UHT Tetra Pak Tetra Therm Aseptic Flex / TA Flex (umgebaut)

Location

Germany

Sold

Specifications

ManufacturerTetra Pak
ModelTetra Therm Aseptic Flex / TA Flex (umgebaut)
Year2008
ConditionUsed
Serial NumberT5844130569
Stock Number1113
Type of MachineIndirect UHT Line
Capacity21.000 liter per hour
ProductsWhole milk (± 4% fat)
Temperature Range± 5 - regeneration - ± 139 °C - regeneration - ± 4 °C
Holding tube2 seconds
DrawingHMH 379
Dimensions± 700 x 650 x 260 cm

Description

Indirect UHT plant for the production of UHT / sterile whole milk by a Tubular Heat Exchanger (THE) system. Capacity up to 21.000 liter per hour. The indirect heating temperature is up to a maximum of 139 °C. Holding time set at 2 seconds.


Line existing out of:

  • Feed-Module mounted on a frame work with 2x Alfa Laval LKH25 centrifugal pumps, 1x Grundfoss CRN32 centrifugal pump, closed level tank, pneumatic valves and flowtransmitter.
  • Tubular Heat Exchanger, pre heater, regeneration and cooler (Tetra Pak Tetra Spiraflo C, 9x model CM 129/27x16C-6, length 6 meter, shell: 10 bar / 160 °C / 40,6 liter volume per tube, medium water and tubes: 25 bar / 160 °C, 28,1 liter volume per tube, contents milk and 1x model model CM 129/27x16S-6, length 6 meter, shell: 10 bar / 180 °C / 40,6 liter volume per tube, medium steam and tubes: 25 bar / 180 °C, 28,1 liter volume per tube, contents milk and 10x model CMR 129/19x20C-6, length 6 meter, shell: 10 bar / 160 °C / 37,4 liter volume per tube, medium water and tubes: 25 bar / 160 °C, 30,7 liter volume per tube, contents milk)
  • Tubular Heat Exchanger, high heater (Tetra Pak Tetra Spiraflo C, 12x model CM 129/19x16S-6, length 6 meter, shell: 10 bar / 180 °C / 50 liter volume per tube, medium water and tubes: 25 bar / 180 °C, 20,4 liter volume per tube, contents milk and 1x model CD 129/1x76C-6, length 6 meter, shell: 10 bar / 180 °C / 45,7 liter volume per tube, medium water and tubes: 25 bar / 180 °C, 26,6 liter volume per tube, contents milk)
  • Holding tube is in a separate frame, 2 seconds, hanging on the roof.


Excluding:

  • Controls / control panel.


Additional features:

The line is originally build in 2008 as a Tetra Therm Aseptic VTIS 100 with VTIS injection system with Tubular Heat Exchanger but on request of the client this unit is converted and re-designed in 2011 by Tetra Pak Sweden according ordernr 907174555 / Rebuilding job S1083225-02 to a TA Flex model with an indirect heating principle.


Line is per direct available and can / will be dismantled from the factory in Germany, latest in ± KW35 - 2024.